Grindmaster RAPS400E Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Kaffeemaschinen Grindmaster RAPS400E herunter. Grindmaster RAPS400E User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 36
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Shuttle Brewer & Airpot/Shuttle Brew ers
Operation and Instruction Man u al
For Models P300E, P400E, P400ESHP, RAP300E,
RAP400E, RAPS300E, RAPS400E
Installation:
See rough-in drawings in this manual for di men sions and lo ca tions of
electric and water input.
Set-Up/Position
1) Remove the brewer from the packing material and attach its legs.
2) Position the brewer on a strong, stable table or counter. Check
the level front to back and side to side. Adjust the legs to the cor-
rect level.
IMPORTANT:
THE PERSON INSTALLING THIS APPLIANCE IS RESPONSIBLE
FOR ENSURING THAT ELECTRIC AND WATER CONNECTIONS
MEET THE RE QUIRE MENTS OF THE NATIONAL ELECTRIC
CODE, NATIONAL PLUMBING CODE, AND ANY LOCAL
ORDINANCES.
The electric and water hook-up locations are behind the front pan el.
Re move the four screws fastening this panel for access to these
con nec tions.
Table of Contents
Installation and Start-up ....................................... 1-2
Warning Labels ...........................................................3
Operation .......................................................... 4
Adjustments ........................................................ 5-8
Care and Cleaning ............................................... 9-10
Service ............................................................... 10-11
Troubleshooting
Filling Problems ....................................... 12
Heating Problems ................................. 13
Brewing Problems ................................ 14
Parts Illustrations
Models P300E & P400E ....................... 15
Model P400ESHP .....................................16
Model RAP400E ..................................... 17
Model RAPS400E ................................... 18
VSB-400................................................ 19
Shuttle CS-LL .......................................... 20
Rough-In Drawings
Model P300........................................................... 21
Model P400 & P400ESHP ...................... 22
Model RAP300 ......................................... 23
Model RAP400 ........................................ 24
Model RAPS300 ....................................... 25
Model RAPS400 ..................................... 26
VSB-300 .................................................. 27
VSB-400 ................................................ 28
Wiring Diagrams
P300E/P400E with 1 Batch Timer ......... 29
P300E/P400E with 2 Batch Timer........ 30
RAP300E/RAP400E................................31
RAPS300E/RAPS400E........................32
P400ESHP ...........................................33
Drawing #091-548 .................................34
Drawing #091-182 .....................................35
Water Hook-up
1) The water line may enter through holes on the rear or the bottom of the brewer. Use the right hand opening for water.
2) Use 3/8" copper or flexible water line to prevent strain. Do not use low temperature plastic tubing. The connection
to the fill valve is 3/8" flare.
3) Water line pressure must be from 30 to 70 psi.
4) Hot (up to 160°F) or cold water may be used. Hot water offers faster recovery between brews.
5) Install a shut-off valve near the brewer.
6) Installing a filtering system can improve the taste of brewed coffee and extend the life of the brewer. If your water
has high calcium (lime), chlorine, or iron content, this is especially important. The filter should be the lime inhibiting
type if cold water is used. Contact your local water treatment professional regarding the type of filter you should use
based on water quality and volume of water used.
© Grindmaster Corporation, 1998
PRINTED IN U.S.A.
0307 FORM # AM-309-08
Part # 090-077
Prior authorization must be obtained from Grindmaster Corporation for all warranty claims.
Grindmaster Corporation
4003 Collins Lane
Louisville, KY 40245 USA
(502) 425-4776
(800) 695-4500 (USA & Canada only)
(800) 568-5715 (Technical Service Only)
FAX (502) 425-4664
www.grindmaster.com
WARNING
ELECTRIC SHOCK HAZARD!
Installation of this appliance should be performed by
qualified service per son nel only. Improper installation
could result in elec tro cu tion.
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - RAP400E, RAPS300E, RAPS400E

Shuttle Brewer & Airpot/Shuttle Brew ersOperation and Instruction Man u alFor Models P300E, P400E, P400ESHP, RAP300E,RAP400E, RAPS300E, RAPS400EIn

Seite 2 - Installation (con't)

Page 10Shuttle Brewers & Airpot/Shuttle BrewersWeekly or Bi-Weekly, Depending on Use1) Fill shuttles with one gallon, 2/3 full, of hot water.2) Po

Seite 3 - Warning Labels

Page 11Shuttle Brewers & Airpot/Shuttle BrewersService (con't)Drain Water TankAlways empty the tank before shipping.Note: Brewer may contain

Seite 4 - Operation

Page 12Shuttle Brewers & Airpot/Shuttle BrewersTroubleshooting: Filling, Heating, and BrewingOverfilling watertank even whenpower is off.Fill val

Seite 5 - Adjustments

Page 13Shuttle Brewers & Airpot/Shuttle BrewersIf you still need help, call our Technical Service Department at (502) 425-4776 or (800) 695-4500 (

Seite 6 - BYPASS VALVE

Page 14Shuttle Brewers & Airpot/Shuttle BrewersTroubleshooting: Filling, Heating, and BrewingBrewing ProblemsThe brewing system consists of the f

Seite 7

Page 15Shuttle Brewers & Airpot/Shuttle BrewersParts Illustration for Models P300E & P400EItem Part # Description Item Part # Description1 A54

Seite 8

Page 16Shuttle Brewers & Airpot/Shuttle BrewersParts Illustration for Model P400ESHPItem Part # Description Item Part # Description1 A545-034 LEG,

Seite 9 - Cleaning

Page 17Shuttle Brewers & Airpot/Shuttle BrewersParts Illustration for Model RAP400EItem Part # Description Item Part # Description1 A548-072LEG, R

Seite 10

Page 18Shuttle Brewers & Airpot/Shuttle BrewersParts Illustration for Model RAPS400EFRONTItem Part # Description Item Part # Description1 A545-034

Seite 11 - Service (con't)

Page 19Shuttle Brewers & Airpot/Shuttle BrewersParts Illustration for Model VSB-400Item Part # Description Item Part # Description1 A545-034 LEG,

Seite 12

Page 2Shuttle Brewers & Airpot/Shuttle BrewersInstallation (con't)Electric Hook-up1) The electric ratings for your brewer are printed on its

Seite 13

Page 20Shuttle Brewers & Airpot/Shuttle BrewersParts Illustration for Shuttle CS-LLItem Part # Description1 A537-053 FAUCET MODEL ES2 A522078SHANK

Seite 14

Page 21Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model P-300

Seite 15 - DIFFERENT PARTS

Page 22Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model P-400 & P-400ESHP

Seite 16

Page 23Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model RAP-300

Seite 17

Page 24Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model RAP-400

Seite 18

Page 25Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model RAPS-300

Seite 19

Page 26Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model RAPS-400

Seite 20 - FAUCET ASSEMBLY

Page 27Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model VSB-300WWWWW A TERIMS

Seite 21

Page 28Shuttle Brewers & Airpot/Shuttle BrewersRough-In Drawing for Model VSB-400

Seite 22

Page 29Shuttle Brewers & Airpot/Shuttle BrewersWiring Diagram for P300E/P400E, with 1 Batch TimerNOTE: THIS DRAWING SHOWS COMPONENTS ONSTANDARD M

Seite 23

Page 3Shuttle Brewers & Airpot/Shuttle BrewersWarning LabelsThe following warning labels were on your dispenser when it was shipped from the facto

Seite 24

Shuttle Brewers & Airpot/Shuttle BrewersPage 30Wiring Diagram for P300E/P400E, with 2 Batch TimerNOTE: THIS DRAWING SHOWS COMPONENTS ONSTANDARD M

Seite 25

Page 31Shuttle Brewers & Airpot/Shuttle BrewersWiring Diagram for RAP300E/400E NOTE: THIS DRAWING SHOWS COMPONENTS ONSTANDARD MODEL ONLY. SEE 09

Seite 26

Page 32Shuttle Brewers & Airpot/Shuttle BrewersWiring Diagram for RAPS 300/400ENOTE: 1) TWO SETS OF RECEPTACLE COMPONENTS ONLYPROVIDED ON TWIN R

Seite 27

Page 33Shuttle Brewers & Airpot/Shuttle BrewersWiring Diagram for P-400ESHP

Seite 28

Page 34Shuttle Brewers & Airpot/Shuttle BrewersWiring Diagram #091-548NOTE: 1) ONE GROUP OF WARMER COMPONENTS PERBREW HEAD ON P AND RAPS MODELS.

Seite 29 - OF BREWER OPTIONS

Page 35Shuttle Brewers & Airpot/Shuttle BrewersWiring Diagram #091-182T3 T3 T3 1 1 T4 AT2 T3 T3 T4 T4 T4 BT2 T3 T3 1 1 T1 CT3 T3 T3 T1 T1 T4 DT2 T

Seite 30

Grindmaster® Coffee Grinders and Brewers • PrecisionBrew™ Brewing Systems • Espressimo® Espresso MachinesCrathco® Hot Beverage Dispensers • Crathco® C

Seite 31 - Drawing #091-545

Page 4Shuttle Brewers & Airpot/Shuttle BrewersOperation1) RAPS Brewers require the accessory warmer base placed over the pegs on the brewshelf bef

Seite 32 - Drawing #091-523

Page 5Shuttle Brewers & Airpot/Shuttle BrewersAdjustmentsAll adjustable components are located under the top cover. To access these parts:1) Shut

Seite 33 - Wiring Diagram for P-400ESHP

Page 6Shuttle Brewers & Airpot/Shuttle BrewersTwo Batch Timer with Knob Adjustment, See Figure 2:This timer is adjustable from 15 seconds to 5 min

Seite 34 - Wiring Diagram #091-548

Page 7Shuttle Brewers & Airpot/Shuttle BrewersTo Adjust the Bypass:1) Shut off and open brewer as described at the beginning of the adjustments se

Seite 35 - Wiring Diagram #091-182

Page 8Shuttle Brewers & Airpot/Shuttle Brewers4) If the maximum temperature adjustment needs to be increased, insert a small flat screwdriverinto

Seite 36 - Part # 090-077

Page 9Shuttle Brewers & Airpot/Shuttle BrewersCleaningAfter Each Brew:1) Dispose of grounds and rinse brew basket.2) Rinse shuttle or airpot conta

Verwandte Modelle: RAP400E | RAP300E |